Kogeneracja, zasilacze UPS, falowniki, soft-starty

UPS Master MPS 10-100kVA

The MPS UPS provides maximum protection and high-quality backup power supply for mission-critical equipment. The UPS is ideal for IT centres, hospitals, telecommunications and industry. The MPS is an on-line UPS with double conversion (VFI SS 111 - IEC EN 62040-3) and a transformer that provides galvanic isolation for the inverter. Designed with three phases on the input and one on the output 3:1.

Main features

  • Robust and reliable
  • Galvanic isolation
  • High overload resistance
  • Wide range of parallel configurations
  • cosφ = 0.9

Characteristics

The Master MPS is designed for the most critical applications, from IT systems to demanding industrial environments, where quality and continuity of power supply are important. It guarantees maximum power and the ability to operate up to 6 units in parallel.

Battery protection system in the Master MPS UPS

The battery protection system of the Master MPS UPS incorporates a number of features designed to optimise battery management and achieve the best performance and extended battery life.

  • Dual level charging to optimise current draw and reduce charging time
  • Temperature compensation and deep discharge battery protection to improve battery life and reduce battery ageing
  • Charge locking system to reduce electrolyte consumption and extend the life of batteries VRLA.
  • Test for quick battery diagnostics

Installation of the UPS Master MPS

The UPS Master MPS does not require a large amount of space for installation: only 0.64 m² for 200 kVA of power. The panel for servicing all major components of the UPS is located at the front of the unit. In addition, the fan is located on top of the UPS cover.

Reliability and availability of the Master MPS UPS

  • Extensive configuration options of parallel operation .
  • Hot System Expansion (HSE) - allows new UPS to be added to an existing system, without having to shut down the UPS in operation. This guarantees maximum protection of the supplied equipment, even during system expansion.
  • Maximum availability levels. The system is "fault-tolerant". - in the event of damage to one of the bus cables in parallel operation, the power supply continues with an alarm signal.
  • Efficiency Control System (ECS) - a system designed to optimise the operational efficiency of parallel operation.

 

UPS Master MPS 60 kVA środek

 

Specification

UPS Master MPM 10 BAT

UPS Master MPM 15 BAT

UPS Master MPM 20 BAT

UPS Master MPM 30

UPS Master MPM 40

UPS Master MPM 60

UPS Master MPM 100

UPS model i moc

Model:
UPS Master MPM 10 BAT
Active power [W]:
9000
Nominal power [VA]:
10000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% full load
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
60 dBA w trybie ECO
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
555x740x1400
Weight without battery [Kg]:
200
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 15 BAT
Active power [W]:
13500
Nominal power [VA]:
15000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% dla pelnego obciążenia
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
60 dBA in ECO mode
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
555x740x1400
Weight without battery [Kg]:
220
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 20 BAT
Active power [W]:
18000
Nominal power [VA]:
20000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% full load
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
60 dBA in ECO mode
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
555x740x1400
Weight without battery [Kg]:
230
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 30
Active power [W]:
27000
Nominal power [VA]:
30000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% full load
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
62 dBA in ECO mode
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
555x740x1400
Weight without battery [Kg]:
255
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 40
Active power [W]:
36000
Nominal power [VA]:
40000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% full load
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
62 dBA in ECO mode
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
555x740x1400
Weight without battery [Kg]:
302
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 60
Active power [W]:
54000
Nominal power [VA]:
60000

Input

Voltage:
380/400/415 V 3 phases
Voltage tolerance:
400 V +20% -25% full load
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-phase+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% for 60 min.; 125% for 10 min.; 150% for 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
62 dBA w trybie ECO
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
800x740x1400
Weight without battery [Kg]:
416
Parallel operation:
yes

UPS model i moc

Model:
UPS Master MPM 100
Active power [W]:
90000
Nominal power [VA]:
100000

Input

Voltage:
380/400/415 V 3 fazy
Voltage tolerance:
400 V +20% -25% dla pelnego obciążenia
Frequency [Hz]:
45-65
Frequency tolerance:
+/-2% (selectable from front panel from 1% do 5% )

By-pass

Voltage [V]:
220/230/240 1-faza+N
Frequency:
50/60 Hz (selectable)

Output

Voltage:
220/230/240 1 phase+N (selectable)
Voltage static stability:
+/-1%
Dynamic stability:
+/-5% in 10 s
Crest factor:
3:1
Frequency [Hz]:
50/60 selectable
Frequency stability on battery mode:
0.05%
Transfer time [ms]:
0
Overload:
110% przez 60 min.; 125% przez 10 min.; 150% przez 1 min.

Others

Efficiency:
>98% in ECO mode
Batteries:
VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels
Communications:
Double RS232 + dry contacts + 2 slots for communications interface
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
+20 - +25
Relative humidity:
5-95% non-condensing
Noise level:
62 dBA w trybie ECO
Colour:
Dark grey RAL 7016
Dimensions (WxDxH) [mm]:
800x800x1900
Weight without battery [Kg]:
665
Parallel operation:
yes

Cross-selling products

Karta NetMan 204 Plus

Karta NetMan 204 Plus

Karta NetMan 204 Plus pozwala na zarządzanie UPS-em bezpośrednio połączonym poprzez LAN 10/100 Mb z…

More 
Karta MultiCOM 302

Karta MultiCOM 302

MultiCom 302 pozwala na monitorowanie UPS-a za pomocą protokołu Modbus/JBUS poprzez łącze RS232 l…

More 
Karta MultiCOM 352

Karta MultiCOM 352

Karta MultiCOM 352 umożliwia przyłączenie dwóch urządzeń do jednego portu szeregowego zasilacza UPS…

More 
Karta MultiCOM 411

Karta MultiCOM 411

Karta MultiCOM 411 umożliwia podłączenie zasilacza UPS do sieci Profibus DP (Decentralised Peripher…

More 
Karta MultiCOM 421

Karta MultiCOM 421

MultiCOM 421 to karta komunikacyjna, która łączy zasilacz UPS z siecią PROFINET-IO. W środowiskach …

More 

Ask about the product

Do you prefer to contact us by phone?

Our offer

Accessibility settings
Line height
Letter spacing
No animations
Reading line
Speech
No images
Focus on content
Bigger cursor
Hotkeys