UPS Master MPS 10-100kVA
Main features
- Robust and reliable
- Galvanic isolation
- High overload resistance
- Wide range of parallel configurations
- cosφ = 0.9
Characteristics
The Master MPS is designed for the most critical applications, from IT systems to demanding industrial environments, where quality and continuity of power supply are important. It guarantees maximum power and the ability to operate up to 6 units in parallel.
Battery protection system in the Master MPS UPS
The battery protection system of the Master MPS UPS incorporates a number of features designed to optimise battery management and achieve the best performance and extended battery life.
- Dual level charging to optimise current draw and reduce charging time
- Temperature compensation and deep discharge battery protection to improve battery life and reduce battery ageing
- Charge locking system to reduce electrolyte consumption and extend the life of batteries VRLA.
- Test for quick battery diagnostics
Installation of the UPS Master MPS
The UPS Master MPS does not require a large amount of space for installation: only 0.64 m² for 200 kVA of power. The panel for servicing all major components of the UPS is located at the front of the unit. In addition, the fan is located on top of the UPS cover.
Reliability and availability of the Master MPS UPS
- Extensive configuration options of parallel operation .
- Hot System Expansion (HSE) - allows new UPS to be added to an existing system, without having to shut down the UPS in operation. This guarantees maximum protection of the supplied equipment, even during system expansion.
- Maximum availability levels. The system is "fault-tolerant". - in the event of damage to one of the bus cables in parallel operation, the power supply continues with an alarm signal.
- Efficiency Control System (ECS) - a system designed to optimise the operational efficiency of parallel operation.
Specification
UPS Master MPM 10 BAT
UPS Master MPM 15 BAT
UPS Master MPM 20 BAT
UPS Master MPM 30
UPS Master MPM 40
UPS Master MPM 60
UPS Master MPM 100
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
UPS model i moc
Input
By-pass
Output
Others
Cross-selling products
Karta NetMan 204 Plus
More
Karta MultiCOM 302
More
Karta MultiCOM 352
More
Karta MultiCOM 411
More
Karta MultiCOM 421
More