Master Industraial UPS has been created for industrial environment and guarantees maximum protection for all applications, especially in industries such as petrochemicals, energy distribution, power plants. Master Industrial UPS is manufactured in true on-line double conversion typology (VFI class SS 111, according to IEC EN 62040-3).
Master Industrial is designed for harsh industrial environments with vibrations, mechanical stresses and high dust levels.
High short circuit current
High short-circuit current: ICC = 3, makes the UPS Master Industrial suitable for equipment requiring high quality connection currents.
Master Industarial UPS 220V
The DC circuit of the UPS unit is designed for use with an external 220 Vdc battery bank (108 to 114 two-volt batteries).
Ventilation in the UPS
The UPS has redundant fans. Each is monitored and an alarm is sounded in the event of a failure.
Specification
UPS Master Industrial MIM 30
UPS Master Industrial MIM 40
UPS Master Industrial MIM 60
UPS Master Industrial MIM 80
UPS model i moc
Model:
UPS Master Industrial MIM 30
Active power [W]:
24000
Nominal power [VA]:
30000
Input
Voltage:
400 V 3-phase
Voltage tolerance:
400 V +/-20%
Frequency [Hz]:
50 or 60 Hz with autorange
Frequency tolerance:
45 - 65 Hz
Power factor:
>0,93%
Output
Voltage:
230 V 1-phase
Total harmonic distortion THDv:
1% - linear load; <3% - non-linear load
Crest factor:
3:1
Waveform:
Sinewave
Frequency [Hz]:
50/60 selectable
Transfer time [ms]:
0
Overload:
110% for 60 min; 125% for 10 min; 150% for1 min.
Others
Efficiency:
>94%
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
0ºC-40ºC
Relative humidity:
5-95% non-condensing
Noise level:
68-70 dBA
Dimensions (WxDxH) [mm]:
800x800x1900
Net weight [Kg]:
640
UPS model i moc
Model:
UPS Master Industrial MIM 40
Active power [W]:
32000
Nominal power [VA]:
40000
Input
Voltage:
400 V 3-phase
Voltage tolerance:
400 V +/-20%
Frequency [Hz]:
50 or 60 Hz with autorange
Frequency tolerance:
45 - 65 Hz
Power factor:
>0,93%
Output
Voltage:
230 V 1-phase
Total harmonic distortion THDv:
<1% - linear load; <3% - non-linear load
Crest factor:
3:1
Waveform:
Sinewave
Frequency [Hz]:
50/60 selectable
Transfer time [ms]:
0
Overload:
110% for 60 min; 125% for 10 min; 150% for 1 min.
Others
Efficiency:
>94%
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
0ºC-40ºC
Relative humidity:
5-95% non-condensing
Noise level:
68-70 dBA
Dimensions (WxDxH) [mm]:
800x800x1900
Net weight [Kg]:
650
UPS model i moc
Model:
UPS Master Industrial MIM 60
Active power [W]:
48000
Nominal power [VA]:
60000
Input
Voltage:
400 V 3-phase
Voltage tolerance:
400 V +/-20%
Frequency [Hz]:
50 or 60 Hz with autorange
Frequency tolerance:
45 - 65 Hz
Power factor:
>0,93%
Output
Voltage:
230 V 1-phase
Total harmonic distortion THDv:
<1% - linear load; <3% - non-linear load
Crest factor:
3:1
Waveform:
Sinewave
Frequency [Hz]:
50/60 selectable
Transfer time [ms]:
0
Overload:
110% for 60 min; 125% for 10 min; 150% for 1 min.
Others
Efficiency:
>94%
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Protection degree:
IP 20
Operating temperature [ºC]:
0ºC-40ºC
Relative humidity:
5-95% non-condensing
Noise level:
68-70 dBA
Dimensions (WxDxH) [mm]:
1200x800x1900
Net weight [Kg]:
910
UPS model i moc
Model:
UPS Master Industrial MIM 80
Active power [W]:
64000
Nominal power [VA]:
80000
Input
Voltage:
400 V 3-phase
Voltage tolerance:
400 V +/-20%
Frequency [Hz]:
50 or 60 Hz with autorange
Frequency tolerance:
45 - 65 Hz
Power factor:
>0,93%
Output
Voltage:
230 V 1-phase
Total harmonic distortion THDv:
1% - linear load; <3% - non-linear load
Crest factor:
3:1
Waveform:
Sinewave
Frequency [Hz]:
50/60 selectable
Transfer time [ms]:
0
Overload:
110% for 60 min; 125% for 10 min; 150% for 1 min.
Others
Efficiency:
>94%
Standards:
European directives: L V 2014/35/EU low voltage; EMC 2014/30/EU electromagnetic compatibility -- Directive and Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant -- Classification in accordance with IEC 62040-3 VFI - SS - 111
Below you can change the cookie settings of us and our partners. Our use of analytics and marketing cookies requires your consent. You can find more information about the different categories of cookies we use on the website below. If you wish to accept all cookies, click "Accept all". If, on the other hand, you want us to use only essential cookies, click "Save settings and close". To change your cookie preferences, move the slider next to the selected category. You have the right to see your settings and to change them at any time.
Base cookies
Our use of essential cookies is necessary for the proper functioning of the website. These cookies are installed in particular for the purposes of remembering login sessions or filling in forms, as well as for setting privacy options.
Analytical cookies
Analytical cookies allow us to see the number of visits and sources of traffic to our site. They help us to identify which pages are more and which are less popular, and to understand how users move around the site. This allows us to study statistics and improve the performance of our site. The information collected by these cookies is aggregated, so they are not intended to establish your identity. If you do not allow these cookies to be used, we will not know when you have visited our website.
Advertising cookies
Advertising cookies allow us to tailor the advertising content displayed to your interests, not only on our website, but also outside of it. They may be installed by advertising partners through our website. Based on the information from these cookies and your activity on other sites, your interest profile is built. Advertising cookies do not store your personal data directly, but identify your web browser and hardware. If you do not allow these cookies to be used, we will still be able to show you advertisements, but they will not be tailored to your preferences.
Advertising preferences
Preference cookies allow the site to remember information that changes the appearance or functioning of the site, such as your preferred language or the region in which you are located.