Main features
- Output power factor (Power Factor) PF = 1.0
- 99% efficiency in ECO mode
- Efficiency in Online mode 95.5%
- Frequency 50 Hz/60 HZ
- Compact, small footprint
- True online - pure sine wave voltage
- Zero switchover time
- Built-in service bypass
- EPO interfaces
- Cold start function
Characteristics
Communication and management of Omega 60 kVA UPS
Omega 60 kVA UPS has a built-in LCD panel for direct management of the power supply and checking its status. In addition, it has an RS 232 and USB communication port. It also has an SNMP module for managing the unit from the LAN.
UPS Omega 60 is the best solution for:
- Industry
- Transport
- Banks
- Hospitals
- Shopping centres
- Data centres
- Institutions
- Media
Advanced features in Omega 60 kVA UPS
Online mode
Designed for highly sensitive loads. The UPS output voltage is not grid-dependent as it comes from the inverter. Omega uses on-line double conversion technology based on full digital DSP control to ensure high efficiency and high power density of the power supply.
By-pass mode
In the event of an inverter failure, inverter overload or manual switchover to bypass mode and other failures or anomalies - the UPS will switch the power supply from the inverter output to the static bypass and the load will be supplied directly by the bypass.
Battery mode
Gdy napięcie sieciowe jest nieprawidłowe, UPS automatycznie przełącza się w tryb pracy bateryjnej. W tym czasie zasilacz pozyskuje energię z baterii, podnosi napięcie poprzez obwód podwyższania napięcia, a następnie podaje napięcie AC do odbiornika poprzez falownik, zasilając odbiornik ciągłym i nieprzerwanym zasilaniem AC wysokiej jakości.
Service bypass mode
If maintenance or repair of the UPS is required, the service bypass switch can be activated. The UPS will operate in service by-pass mode and supply power via the by-pass line and not via the main power unit. During this time, the replaceable unit in the unit can be serviced.
ECO mode
ECO mode is an economical UPS operating mode that can be set via the LCD interface. In ECO mode, when the input voltage of the bypass is within the ECO voltage range, power is supplied by the bypass and the inverter is in standby mode. When the input voltage of the bypass exceeds the acceptable voltage range, ECO power is supplied to the load via the inverter rather than via the bypass. ECO mode increases the overall efficiency of the UPS.
Specification
CES Omega 60
UPS model i moc
Input
Output
Komunikacja
Others